Search
Close this search box.
Categories:

BFMM1L Series Leakage Circuit Breaker

BFMM1L series residual current circuit breaker is mainly applicable to the distribution network with AC 50Hz.rated voltage of 40oV and rated current of 80oA Indirect contact protection can also be used to prevent fire hazard caused by equipment insulation damage and ground fault current, and can be used to distribute electric energy It can also be used for infrequent line switching and infrequent motor starting.Conventional with residual current The working power sampling of the leakage protection module of the protective circuit breaker is two-phase, and the circuit breaker of this series is three-phase. If one phase is missing, the leakage protection module of the circuit breaker will still work Can work normally: The rated residual operating current and maximum breaking time can be adjusted on site according to the actual situation;When the phase voltage is reduced to 5ov, the leakage protection module can still Normal operation;With leakage alarm output function. Compliance with standards:GB/T14048.2

Model And Meaning

BFMML Series Leakage Circuit Breaker Model And Meaning
  1. (1)The circuit breaker for power distribution has no code; Circuit breaker for motor protection is indicated by 2 (fill in D)
  2. (2)No code for direct operation of handle; Electric operation is represented by p; Manual operation is represented by Z.

Functional Features

The electric circuit breaker is a new electronic leakage circuit breaker imported and absorbed from abroad. The working current of the leakage protection module is sampled in three phases, and the leakage module can still work normally in case of power shortage in any phase The installation size is the same as that of molded case circuit breaker BFMM1L, Mitsubishi NF and other products. Therefore, the installation is in good condition.Small size, high segmentation ability, short arc, strong anti-interference, etc. With leakage action indication, the remaining The residual leakage electric action current (MA) is adjustable in three gears and the time is adjustable in three gears. Can be installed for customers, shunt, auxiliary,alarm, undervoltage and other accessories.  

Main Technical Parameters

Model BFMM1L-125 BFMM1L-250 BFMM1L-400 BFMM1L-630 800
Maximum rated current of shell frame level Inm(A) 125 250 400 800
Rated current in (A) 10,16,20,25,32,
40,50,63,80,100,125
100,125,140,160,
180,200,225,250
225,250,315,
350,400
400,500,630,
700,800
Number of poles 3 4 3 4 3 4 3 4
Rated insulation voltage UI (V) AC 800
Rated working voltage Ue (V) AC 400
Rated impulse withstand voltage Uimp (V) 8000 8000 8000 8000
Arcing distance (mm) 50 50 100 100
Breaking capacity level L M H L M H M H M H
Limit short circuit breaking
capacity LCU (KA)
AC 400V 35 70 85 35 70 85 70 100 70 100
Operating short-circuit breaking
capacity ICs (KA)
AC 400V 25 50 65 25 50 65 50 65 50 65
Rated residual short-circuit making (breaking)
capacityIΔm(KA)
8.75 12.5 21 8.75 12.5 21 17.5 25 17.5 25
Rated residual operating
currentiΔn (MA)
Non delay type 30/100/500
100/300/500
30/100/500
100/300/500
100/300/500 100/300/500
Slo-Blo 100/300/500 100/300/500 100/300/500 300/500/100
Rated residual non operating current I△no (MA) 1/2 IΔn 1/2 IΔn 1/2 IΔn 1/2 IΔn
Operating performance times Electrify 1500 1000 1000 1000
No electricity 8500 7000 4000 4000
Total times 10000 8000 5000 5000
Residual current protection action time IΔn 2 IΔn 5 IΔn 10 IΔn
Maximum breaking time s Non delay type 0.2 0.1 0.04 0.04
Slo-Blo 0.5/1.15/2.15 0.35/1/2 0.25/0.9/1.9 0.25/0.9/1.9

Installation And Overall Dimension Drawing

Circuit breaker model BFMM1L-63 BFMM1L-100(125) BFMM1L-225(250) BFMM1L-400 BFMM1L-630 BFMM1L-800 BFMM1L-1250
(1600)
Number of poles 3 4 3 2 4 3 2 4 3 4 3 4 3 4 3
Overall
dimension mm
Long L 135 150 165 257 270 280
Width W 76 103 92 65 122 107 75 142 140 184 182 240 210 280
High H 74 82 82 68 87 87 104 100 108 103
Installation
dimension mm
a 25 50 30 60 35 70 44 88 58 118 70 14
b 117 117 129 1129 129 126 126 126 215 215 200 200 243 243
фd 3.5 3.5 4.5 4.5 4.5 5.5 5.5 5.5 6.5 6.5 7 7 7 7
Wiring size
behind the
board
a1 25 30 35 44 58 70
b1 117 132 144 225 234 243
d1 18 22 24 32 40 48
H3 52 65 70 70 70 75
H4 75 100 110 120 120 125
H5 44 68 66 60 65
H6 66 108 110 120 125
H7 50 50 60 60
H8 62 69.5 83.5 92
H9 74 84.5 106.5 110
H10 17.5 17.5 21 21
L5 92 94 160 169
L6 168 163 279 299
K 6.5 6.5 8.5 8.5
J 56 54 129 123

 

BFMML Series Leakage Circuit Breaker Installation And Overall Dimension Drawing

BFMML Series Leakage Circuit Breaker Installation And Overall Dimension Drawing

BFMML Series Leakage Circuit Breaker Installation And Overall Dimension Drawing

Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected] or use the following enquiry form. Please allow us to provide you with the best service.

Other Related Products

ZYMM L P Black Cover
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.
Get A Quote
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.
Select Language:
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.