Construction and Feature

Provides protection against earth faultleakage current and function of isolation High short-circuit current withstand capacity Contact position indication Equipped with finger protected connection terminals Fire resistant plastic parts endures abnormal heating and strong impact Automatically disconnect the circuit when earth faultleakage current occurs and exceeds the rated sensitivity. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.

Technical Data

  • Mode: electro-magnetic type, electronic type
  • Residual current characteristics: A, AC
  • Pole No.:2,4
  • Rated making and breaking capacity:630A
  • Rated current(A):25,40,63,80,100
  • Rated voltage: AC 230(240)400(415)
  • Rated frequency: 50/60Hz
  • Rated residual operating current I△n(A): 0.03, 0.1, 0.3, 0.5
  • Rated residual non operating current I△no: 0.51△n
  • Rated conditional short-circuit current Inc: 6kA
  • Rated conditional residual short-circut Current l△c: 6 kA
  • Tripping duration: instantaneous tripping ≤0.3s(0.1)
  • Residual tripping current range: 0.51△n-l△n
  • Electro-mechanical endurance: 4000 cycles
  • Connection capacity: Rigid conductor 25mm²
  • Terminal Connection Height: 21mm
  • Connection terminal:Pillar terminal with clamp
  • Fastening torque: 3.0Nm
  • Installation:On symmetrical DIN rail 35.5mm、Panel mounting
  • Protection class:IP20

Shape and installation dimensions

BFRC Residual Current Circuit Breaker Shape and installation dimensions

Wiring Diagram

BFRC Residual Current Circuit Breaker Wiring Diagram

Residual Current Action Breaking Time

type In/A I△n/A Residual Current (△A) Is Corresponding To The Following Breaking Time (S)
IAn 21An 5lAn 5A,10A,20A,50A,100A,200A,500A
general type any value any value 0.3 0.15 0.04 0.04 Max Break-time
S type ≥25 >0.03 0.5 0.2 0.15 0.15 Max Break-time
0.13 0.06 0.05 0.04 Min non-driving time

The general type RCcB whose current I△n is 0.03mA or less can use 0.25A instead of 5I△n.

Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected] or use the following enquiry form. Please allow us to provide you with the best service.

Other Related Products

BF Isolating switch Series
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.
Get A Quote
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.
Select Language:
Welcome to our website. If you have any requests or suggestions,please feel free to email us at  [email protected]  or use the following enquiry form. Please allow us to provide you with the best service.